SF6 Gas Insulated Ring Main Unit
Parameters
No. | Item | Value | |||
1 | Rated Voltage | 24kV | |||
2 | Rated Current | 630A | |||
3 | Rated Frequency | 50Hz/60 Hz | |||
4 | Rated Breaking Current | 630A | |||
5 | Rated Short-circuit Making Current | 50 kA | |||
6 | Rated Peak Withstand Current | Main Circuit | 50 kA | ||
Grounding Switch | 50 kA | ||||
7 | Rated Short-time Withstand Current | Main Circuit | 20 kA/4s | ||
Grounding Switch | 20kA /2s | ||||
8 | Rated Insulation Level | Power Frequency Withstand Voltage | Impulse Withstand Voltage | ||
Between Breakers | 79kV | 145kV | |||
Between Phases | 65kV | 125kV | |||
To earth | 65kV | 125kV | |||
9 | Mechanical Endurance | 5000times | |||
10 | Breaking Times at Full Load | 200times | |||
11 | Main Circuit Resistance | less 200μΩ | |||
12 | Rated Gas Pressure(at above 20°C) | 0.05MPa | |||
13 | SF6 Gas Leakage Rate Per Year | less 0. 1% | |||
14 | Degrees of Protection | Switch Enclosure | IP67 | ||
Kiosk | IP33 |
I. About Product
1. APPLICATION
1.1 The Ring Main Unit is used for the secondary distribution networks.
1.2 The ring main unit is conform to the following standard specifications,
IEC Publications: 60684, 60298, 60420, 60265, 60129, 60056, 60529.
2. SERVICE CONDITIONS
2.1 The ambient temperature does not exceed the range of -40°C~+50°C. Its average value measured over a period of 24 hours does not exceed 40°C.
2.2 The altitude does not exceed 4000M.
2.3 Relative humidity range from 0~100%.
2.4 Earthquake Richter scale: Not over than 8.
2.5 Condensation, heavy pollution and corrosion are all considered while designing.
3. TYPES:
Our standard Ring Main Units are un-extendible type. According customer’s specific requirements, we also can supply the extendible type. Our standard Ring Main Units can be supplied in 25 different configurations suitable for most switching applications in 12/24 kV distribution networks. They represent nearly a complete solution for 12/24 kV secondary distribution networks.
C: Loadbreak Switch; F: Switch and Fuse combination; V: Vacuum Circuit Breaker
CC/CV
CCC/FCC/CCF/CFC/ VCC /CCV/CVC
CCCC/CCCF/CCFF/CFFC/CCCV/CCVV/CVVC
CCCCC/CCCCF/CCCFF/CCFFF/CCCCV/CCCVV/CCVVV
CCCCCC
CCCCCCC
4. MAIN ACCESSOREIS:
1) BAROMETER ( GAS LEAKAGE INDICATION): Barometer is provided to indicate the sufficient and in-sufficient gas pressure.
2) VOLTAGE CONTROL DEVICE AND PHASE COMPARISION TESTING: A voltage control device is installed for each circuit to show if the cable is energized or not. Socks for phase comparison testing are provided.
3) SHORT CIRCUIT INDICATORS: Short circuit indicators can be installed which can be manually re-settable.
4)COUNTER: Counter is installed to show the operating times.
5) OPENING HANDLE: One common operating handle for High Voltage and Earthing switches is provided for each set of Ring Main Unit.
6) PRESSURE RELEASING DEVICE: Each set of Ring Main Unit will be installed a pressure releasing device for releasing the pressure when the inner pressure overpasses the standard.
7) LOW PRESSURE ALARMING DEVICE: With the device, the alarming sound will be given when the pressure lower than the standard.
8) PAD LOCKING: Provision is made for padlocking the load break switches and the earthing switches in either OPEN OR CLOSED position, a parking position for the padlock is provided for each padlocking device.
II. About Factory
1) We have 8 years experience of manufacturing SF6 Ring Main Unit, KYLIN Ring Main Unit is a name that stand for quality and durability.
2))This type and design products are sold well in South Korea, India, Pakistan and Vietnam. Other countries in South America, South-east Asia, Middle East and Africa are our target markets.